OpenPLC on Windows

Archived Website

The information on this website is outdated. It is kept in here for historical purposes only. Please refer to https://autonomylogic.com for the most up to date information about the OpenPLC Project.

Installing OpenPLC on Windows is as easy as it can get! Just download the installer and run it. Please make sure you have a reliable connection to the internet while running the installer as it downloads the latest packages from the web.

The Windows installer also comes bundled with OpenPLC Editor. So, you don’t need to download it separately if you’re installing this on your system.

Once OpenPLC Runtime is installed, you can start it by going to the start menu and launching the OpenPLC Runtime shortcut.

Troubleshooting

In general, OpenPLC installation issues are related to bad directory paths or denied permissions. That’s why it is always recommended to run the installer as admin. In any case, here are some troubleshooting guides for people that are having issues with the installer:

1) Rebase OpenPLC

The first thing to do if OpenPLC is not launching after installation is to run the “Rebase OpenPLC” shortcut from the start menu. It will try to look for and fix general installation problems.

2) Install Cygwin Manually

If rebasing OpenPLC didn’t work, there might be something else affecting your installation, and that’s usually Cygwin. In that case, a manual Cygwin installation might be required. To install Cygwin manually, download the installer from https://cygwin.com/install.html. There are two options: setup-x86_64.exe for 64-bit machines and setup-x86.exe for 32-bit machines. Most likely your computer is a 64-bit machine, so download setup-x86_64.exe and run it. The installation process is very simple. On the first screen, select “Install from Internet”, and on the next screen, make sure you install it inside the OpenPLC folder. That should be C:\Users[your-user-name]\OpenPLC\Runtime. This is very important! If you install Cygwin on another directory, this procedure won’t work. On the next screen, leave the Local Package Directory as default. When you reach the Available Download Sites list, pick the first one and hit next. This will take you to the Select Packages list. On this list, select View Full and search for the packet git. The table will be populated with several packages related to git. Select the one named git (it is just plain git, not cgit or git-cvs or git-gui). With that package selected, on the drop-down box inside the column “New”, select the latest version available for git (at this time of writing it is 2.17.0-1) and hit next.

You will see a summary of all items to be installed. Hit next and let the installation begin. Once Cygwin had finished installing, try launching “Rebase OpenPLC” again from the start menu.

3) Install OpenPLC Manually

If even after installing Cygwin manually you can’t start OpenPLC, then you probably will have to install it manually as well. The process is simple and straightforward. You will need to open Cygwin Terminal and type:

git clone https://github.com/thiagoralves/OpenPLC_v3.git
cd OpenPLC_v3
./install.sh win

After typing these 3 commands, OpenPLC installation will start. It may take a while (up to 15 minutes depending on your computer and internet speed). Once the installation finishes, you can start OpenPLC by launching the OpenPLC Runtime shortcut on the start menu or by typing:

./start_openplc.sh

on Cygwin Terminal.

Running OpenPLC

The OpenPLC runtime has a nice web interface that you can access. While OpenPLC runtime is running, open your browser and type:

localhost:8080

​ Once you access OpenPLC web interface, you should see in your browser window a login page like this:

The default username and password is openplc (login) and openplc (password). This means that the first thing you must do after logging in for the first time is change the default username and password! It is very easy to do that. Just go to the Users menu, click on the OpenPLC User and change the information as you like.

Once you save the changes you will be prompted to login again. Just login with your new credentials and you will be good to go!

Setup Slave I/O

A great way to use OpenPLC on your Windows machine is with slave I/Os. Therefore, your Windows machine can run OpenPLC Runtime and act as a Soft-PLC controlling real boards configured as Slave I/O devices. Go to the Getting \Started page and follow the instructions to setup one of the supported platforms as slave devices. Then, through the web interface, add your slave devices on the “Slave Devices” menu. Keep in mind that slave devices are attached to address 100 onward (i.e. %IX100.0, %IW100, %QX100.0, and %QW100).

My First Project

The Reference menu on this website has a nice tutorial that teaches you how to create your first project. However, if you’re in a hurry, you can download the official Hello World project, which is basically one rung, a button, a timer and a coil, all connected together. The button is attached to %IX0.0 and the coil is attached to %QX0.0. When the button is pressed and released, the coil is energized and remains on for 2 seconds, and then turns off.

Download the project below and open it on OpenPLC Editor. Click on Generate program for OpenPLC Runtime in order to compile the diagram into a ST file. Then upload the ST file to the OpenPLC using the web interface.